Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters

Database
Main subject
Language
Document Type
Year range
1.
Eur J Nucl Med Mol Imaging ; 48(8): 2525-2530, 2021 07.
Article in English | MEDLINE | ID: covidwho-1014121

ABSTRACT

BACKGROUND: This study aimed to analyze the rates of tracheobronchitis signs observed on the ventilation scans of COVID-19 patients with shortness of breath, with comparisons to a non-COVID population. METHODS: Lung scintigraphy was collected in 10 such COVID patients, as well as from a non-COVID population investigated outside the epidemic wave period, on a CZT-SPECT/CT system, with ventilation images recorded with 99mTc-labeled Technegas® and perfusion images with 99mTc-labeled albumin macroaggregates. RESULTS: A diffuse tracheobronchial uptake was observed on the ventilation scans from 3 COVID patients (30%), whereas this rate was 3% (3/90) in the non-COVID group (P = 0.013). These 3 patients had no laryngeal extension of Technegas® uptake and limited parenchymal lung abnormalities. Follow-up scintigraphy demonstrated the withdrawal of tracheobronchitis signs in two cases, and the advent of a severe pulmonary embolism in one. CONCLUSION: Signs of tracheobronchitis may constitute the principal finding on lung SPECT/CT images of COVID-19 patients with shortness of breath.


Subject(s)
COVID-19 , Humans , Lung , SARS-CoV-2 , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL